dc.description.abstract |
A numerical study is conducted to investigate the transport mechanism of laminar mixed
convection in a shear and buoyancy driven cavity having a locally heated lower wall and
moving cooled sidewalls. Effort is focused on the interaction of forced convection with
natural convection. Discretisation of the governing equations is achieved through a finite
difference method. The third order upwind scheme for the convective derivative turns out to
be the most accurate scheme. Parametric studies on the effect of mixed convection parameter,
Gr/Re² (also referred as Richardson number, Ri) in the range 0.1 – 100.
Three different regimes are observed with increasing Ri. When the forced convection
dominates the flow consists of two symmetrical cells. For a precise interval of this number,
this symmetry disappears. Starting from a critical value of the Richardson number, we noted
an abrupt reduction in the number of average Nusselt as well as the apparition of four cells. |
|
dc.language.iso |
fr |
|
dc.publisher |
Constantine : Université Mentouri Constantine |
|
dc.subject |
Génie Mécanique |
|
dc.subject |
G.mécanique: Thermo-fluide |
|
dc.subject |
Convection mixte |
|
dc.subject |
Difference finie |
|
dc.subject |
Schéma upwind |
|
dc.subject |
Mixed convection |
|
dc.subject |
Finite difference method |
|
dc.subject |
Critical Richardson |
|
dc.subject |
الحمل الحراري |
|
dc.subject |
طريقة الفروق المنتهية |
|
dc.title |
Développement d'un programme de calcul de l'écoulement avec transfert de chaleur dans une cavité avec des parois mobiles. |
|
dc.type |
Thesis |
|
dc.coverage |
01 Disponible à la salle de recherche 02 Disponibles au magazin de la B.U.C. 01 CD |
|