DSpace Repository

INFLUENCE OF INJECTORS PLATES SPACING USED IN ACTIVE STRATIFICATION SOLAR TANKS ON THE THERMAL STRATIFICATION

Show simple item record

dc.contributor.author SOTEHI, OUALID
dc.contributor.author CHAKER, ABLA
dc.date.accessioned 2022-05-30T10:23:55Z
dc.date.available 2022-05-30T10:23:55Z
dc.date.issued 2013-12-16
dc.identifier.uri http://depot.umc.edu.dz/handle/123456789/12642
dc.description.abstract The aim of this work is the study using a CFD code, of the thermal stratification in two solar tanks equipped with active stratification devices and having equal volume. The first one equipped with three injectors with parallel plates spaced of 2 cm, while the second is equipped with three parallel plates injectors spaced of 4 cm. The influence of flow rate is highlighted. Results show that increasing the injection flow rate leads to a fast lose of stratification of the storage tank for both solar storage tanks. Thus, for high injection flow rate, the stream creates along both sides of the tank leads to a faster lose of stratification. The second tank with injectors more spaced preserves better the stratification compared with the first tank
dc.language.iso en
dc.publisher Université Frères Mentouri - Constantine 1
dc.subject Thermal stratification
dc.subject injectors
dc.subject solar storage tanks
dc.subject injection flow rate
dc.title INFLUENCE OF INJECTORS PLATES SPACING USED IN ACTIVE STRATIFICATION SOLAR TANKS ON THE THERMAL STRATIFICATION