dc.contributor.author | Zeghloul, Ammar | |
dc.contributor.author | Azzi, Abdelwahid | |
dc.contributor.author | Messilem, Abdelkader | |
dc.contributor.author | Saidj, Faiza | |
dc.date.accessioned | 2022-05-30T09:57:15Z | |
dc.date.available | 2022-05-30T09:57:15Z | |
dc.date.issued | 2015-11-26 | |
dc.identifier.uri | http://depot.umc.edu.dz/handle/123456789/12282 | |
dc.description.abstract | Measurements of upward single and two-phase gas-liquid flow pressure drop through an orifice placed in a vertical pipe are reported. These were achieved using differential pressure transmitters. Six orifices of different diameters and thicknesses have been employed. The superficial velocities of the gas was varied from 0 to 4 m/s and for the liquid from 0.3 to 0.91 m/s. For single-phase flow it was found that the models of Idel’chik [1] and that proposed by Akhter et al. [2] correlate fairely good the orifice single-phase pressure drop coefficient for low open area ratio orifices. Moreover present data have been used to assess the most referenced correlations devoted for predicting two-phase flow pressure drop through orifice. It appeared that those of Morris and Simpson are the most reliable with an error of 7 to 20 % | |
dc.language.iso | en | |
dc.publisher | Université Frères Mentouri - Constantine 1 | |
dc.subject | Orifice | |
dc.subject | single-phase | |
dc.subject | two phase | |
dc.subject | pressure drop | |
dc.subject | multiplier coefficient | |
dc.title | Single- and two-phase flow pressure drop through orifice | |
dc.type | Article |